Fire sprinkler and suppression systems

Fire Protection Engineering

Designed to never be needed.

Fire protection is engineering for the worst day. We design wet, dry, pre-action, and clean-agent suppression systems that protect occupants, assets, and operations, coordinated tightly with mechanical, structural, and architectural so the AHJ has no reason to send the drawings back.

Buildings equipped with automatic sprinklers begin extinguishing fire before firefighters arrive. Fully sprinklered buildings are safer, qualify for lower insurance premiums, and protect business continuity, when the system is engineered to the actual hazard, not a generic template.

Our Approach

Fire Protection Engineering engineering approach

How We Work

Every suppression design begins with the hazard: occupancy classification, commodity, storage height, and water supply. Hydraulic calculations are run against real flow-test data, and insurance carrier requirements (FM Global, IRI) are folded in from day one.

  • Hydraulic calculations against actual flow-test data
  • NFPA 13 / 14 / 20 / 30 / 409 design experience
  • FM Global & insurance carrier compliance built in

Service Capabilities

A.Suppression Systems

  • Wet & dry pipe sprinkler design
  • Pre-action & deluge system design
  • Standpipe & hose connection systems
  • Fire pump & water supply analysis
  • Hydraulic calculations & flow testing
  • Clean-agent suppression (FM-200, Novec, inert)
  • Water-mist systems
  • Foam suppression for hazardous occupancies
  • Kitchen hood & cooking suppression
  • Storage tank fire protection (NFPA 30)

B.Special Occupancy & Hazard

  • High-piled storage & warehouse design
  • Aircraft hangar suppression (NFPA 409)
  • Industrial dust & combustible-materials protection
  • Healthcare fire protection (NFPA 99 / 101)
  • Data center & mission-critical suppression
  • Hazardous materials code consulting
  • Atrium smoke control modeling (CFD)
  • Insurance carrier compliance (FM Global, IRI)

C.Code, Egress & Existing Buildings

  • Performance-based fire engineering
  • Egress & travel-distance analysis
  • Fire & smoke compartmentation design
  • Fire-rated assembly & penetration design
  • Code consulting & AHJ coordination
  • Fire & life safety code reviews
  • Fire flow & water supply studies
  • Site fire main & hydrant design
  • Existing system surveys & upgrade design
  • 3D laser scanning & point-cloud modeling of existing systems
  • Special inspection & third-party plan review

Why Owners Choose KeRi

AHJ-Ready Documents

Drawings detailed and coordinated so plan examiners and field inspectors sign off without resubmission cycles.

Hazard-Matched Design

From high-piled storage to data halls to hangars, systems matched to the real hazard, not copied from the last job.

Insurance Compliance

FM Global and carrier requirements engineered in from the start, protecting both premiums and claims positions.

Have a project worth engineering?

We work with owners, architects, contractors, and developers across higher education, healthcare, pharmaceutical, commercial, mission-critical, and institutional sectors. Bring us in early. Schematic design is where the most expensive mistakes get prevented.

Start a Conversation