Healthcare
Healthcare engineering carries no margin for error. Operating rooms run on isolated power, ORs and ICUs require ASHRAE 170 pressure relationships verified at commissioning, and standby generators must transfer in ten seconds and run for days. We bring deep familiarity with the FGI Guidelines, NFPA 99, Joint Commission expectations, and the operational reality that hospitals never close, which makes every retrofit a phased infection-control puzzle as much as an engineering one.
From full replacement hospitals to a single endoscopy-suite renovation, our healthcare team designs for clinical outcomes, code compliance, and the facility engineer who will troubleshoot the system at 3am.
Our Approach
How We Work
We design healthcare systems around the clinical outcome and the facility engineer who maintains them, with pressure relationships, redundancy, and infection-control phasing settled before construction begins.
- FGI and ASHRAE 170 pressure relationships verified
- NFPA 99 and Joint Commission compliance
- ICRA-phased infection-control retrofits
Representative Project Types
A.Acute & Inpatient Care
- Acute-care & community hospitals
- Patient towers & bed expansions
- ICU, NICU & PICU units
- Operating-room suites
- Hybrid & cardiac cath labs
- Emergency departments
- Labor, delivery & women's services
- Behavioral-health facilities
B.Ambulatory & Specialty
- Medical office buildings (MOB)
- Ambulatory surgery centers (ASC)
- Imaging centers (MRI, CT, PET)
- Cancer & radiation oncology
- Infusion & dialysis centers
- Endoscopy suites
- Rehabilitation & long-term care
- Urgent care & specialty clinics
C.Support & Infrastructure
- Central sterile processing
- Pharmacy & USP 797/800 compounding
- Hospital central energy plants
- Medical-gas system upgrades
- Emergency-power infrastructure
- Pathology & clinical labs
- Decarbonization & LL97 compliance
- Senior & assisted-living facilities

Selected KeRi Experience
Hackensack University Medical Center, data center and IDF room upgrades and a temporary emergency-generator feasibility study. Plus Phelps Memorial Hospital, Daughters of Israel (HVAC evaluation and sprinkler upgrade), and multiple medical office build-outs spanning dental, rheumatology, physical therapy, and family practice.
Why Owners Choose KeRi
No Margin for Error
Isolated power, ASHRAE 170 pressure relationships, and ten-second generator transfer verified at commissioning.
Infection Control Built In
ICRA-phased retrofits engineered around a hospital that never closes.
Code-Fluent
FGI, NFPA 99, and Joint Commission expectations carried from schematic design to survey.